PR6423/014-121 CON031 测量模块EPRO
产品详情资料
示波器显示器包括一个光标——注意图像中的蓝色垂直线——可以在显示器上自由放置以测量到反射源的距离。在节点 22 连接 PROFIBUS 测试仪后,我们的工程师确定反射发生在距 PLC 相邻的网络“另一端”节点约 45 米处。
第一步是检查 PROFIBUS 连接器总线终端设置,该设置正确设置为 ON。接下来,我们的工程师检查了连接器本身,发现连接器内部的总线终端电路有故障。更换此 PROFIBUS 连接器可实现以下功能:
它恢复了正确的总线终端。
网络的信号质量恢复到可接受的水平。
我们成功地了迫使 PLC 进入停止模式的 PROFIBUS 网络故障。以前,由于信号失真太大,PLC 无法接收到每个数据帧。
英文产品详细信息
The oscilloscope display includes a cursor - note the blue vertical line in the image - that can be freely placed on the display to measure the distance to the reflection source. After connecting the PROFIBUS tester at node 22, our engineers determined that the reflection occurred approximately 45 meters away from the "other end" node of the network adjacent to the PLC.
The first step is to check the PROFIBUS connector bus terminal settings, which are correctly set to ON. Next, our engineer inspected the connector itself and found that there was a fault in the bus terminal circuit inside the connector. Replacing this PROFIBUS connector can achieve the following functions:
It restored the correct bus terminal.
The signal quality of the network has been restored to an acceptable level.
We successfully eliminated the PROFIBUS network fault that forced the PLC into stop mode. Previously, due to significant signal distortion, the PLC was unable to receive each data frame.
免责声明:
AMIKON我们销售新产品和停产产品,独立渠道购买此类特色产品。阿米控不是本网站特色产品的授权分销商、经销商或代表。本网站上使用的所有产品名称/产品图片、商标、品牌和徽标均为其各自所有者的财产。带有这些名称,图片、商标、品牌和徽标的产品描述、描写或销售仅用于识别目的,并不表示与任何权利持有人有任何关联或授权。
HONEYWELL | 05701-A-0301 | GE | IC693MDL655 |
GE | IC200MDL241 | GE | IC693MDL646 |
GE | IC200MDD844 | GE | IC693MDL645H |
GE | IC200MDD842 | GE | IC693MDL645 |
GE | IC200MDD840 | GE | IC693MDL632 |
GE | IC200GBI001-GJ | GE | IC693MDL340 |
GE | IC200GBI001 | GE | IC693MDL240 |
GE | IC200CPUE05 | GE | IC693CPU374-KZ |
GE | IC200CPU002 | GE | IC693CPU374 |
GE | IC200CPU001 | GE | IC693CPU364 |