theme theme
您现在的位置:厦门阿米控技术有限公司首页 > 产品中心 > 1C31166G01/1C31116G02模块
2025年01月20日 星期一

产品中心

  • 1C31166G01/1C31116G02模块

  • 更新时间:2025-01-20
  • 联系方式

    18030175270  /  0592-5085207

    吴工 女士

  • 举报
  • 收藏该店铺
  • 已收藏
详细信息

1C31166G01/1C31116G02模块
1C31166G01/1C31116G02模块

产品信息

  • 型号:1C31166G01

  • 别名:输入模块链接控制器

IC200ALG240 IC693ALG223
IC200MDD843 IC693ALG390
IC200MDD840 IC693ALG391
IC200TBX114 IC693ALG392
IC200ALG261 IC693ALG442
IC200TBX040 IC693APU300
IC200TBX010 IC693APU305
IC200AC15 IC693BEm331
IC200AC14 IC693CHS393
IC200ALG262 IC693CPU313特性

1.包含隔离式 RS-232/RS-485 组合端口,可用于串行和网络通信

2.提供四个锁定或脉冲捕获输入和四个中断输入

3.包含内置的独立 20 kHz 高速计数器

4.提供可编程限位开关功能

5.包含两个内置  圈微调电位计,数字量输出范围 0 250

6.提供程序数据性

7.支持浮点数据文件

8.可扩展到***多 136 个 I/O 点

9.与 1762 MicroLogix 扩展 I/O 模块兼容(每个控制器***多有六个模块)

10.提供附加编程/HMI 端口,用于连接到 DF1 全双工兼容设备(***在 MicroLogix 1200R 控制器上)
140ACI03000
140ACI04000
140ACO02000
140AII33010
140AMM09000
140ARI03000
140ARI03010



                                                                                 产品详情资料


可以通过两种方式访问数据日志:通过串行端口使用EnerVista PQM设置。

通过EnerVista PQM设置访问如第6章:软件所述。访问权限是

手动通过串行端口,如下所示:

?在PQM内存映射中设置您希望在1268h访问的数据块

?从块中的64个寄存器读取所需的数据量

以这种方式访问数据日志假设用户知道他们想要的块

访问,并根据每个记录的参数了解其大小

选择以记录。

访问数据日志中数据的***简单方法是读取整个日志并将其导出

数据输入电子表格进行分析(这是EnerVista PQM采用的方法

设置)。这需要定义要读取的块,从块0开始,读取所有128

块内64个寄存器中每个寄存器的数据字节数。然后定义块

1、2、3等,并重复读取每个块的64个寄存器,直到块511。这

需要512次读取,每次读取128字节。然后可以根据参数配置解释数据。

                          产品英文详情资料:


 

The Data Log can be accessed in two ways: using EnerVista PQM Setup via the serial port.

Access via EnerVista PQM Setup is as described in Chapter 6: SOFTWARE. Access is

manually via the serial port as follows:

? Set the Block of data you wish to access at 1268h in the PQM Memory Map

? Read the required amount of data from the 64 Registers in the Block

Accessing the Data Log in this manner assumes that the user knows which Block they wish

to access, and knows the size of each Record based upon the parameters they have

selected to log.

The easiest way to access the data in the Data Log is to read the entire log and export this

data into a spreadsheet for analysis (this is the method incorporated by EnerVista PQM

Setup). This requires defining the Block to be read, starting at Block 0, and reading all 128

bytes of data in each of the 64 Registers within the Block. You would then define Blocks

1,2,3 etc. and repeat the reading of the 64 Registers for each block, until Block 511. This

requires 512 reads of 128 bytes each. The data can then be interpreted based upon the parameter configuration.

GEIC693ALG222本特利 330104-00-04-10-02-05
GEIC693ALG221F本特利330104-00-04-10-02-00
GEIC693ALG221本特利330103-10-14-10-02-05
ABIC693ALG221本特利330103-00-10-10-02-00 
GEIC693ALG220本特利330103-00-10-10-02-00
GEIC693ACC310本特利330103-00-05-50-12-00
GEIC693ACC307本特利330103-00-05-10-02-05
GEIC693ACC302AYOKOGAWAAAI141-S00 S2


免责声明:

AMIKON我们销售新产品和停产产品,独立渠道购买此类特色产品。阿米控不是本网站特色产品的授权分销商、经销商或代表。本网站上使用的所有产品名称/产品图片、商标、品牌和徽标均为其各自所有者的财产。带有这些名称,图片、商标、品牌和徽标的产品描述、描写或销售仅用于识别目的,并不表示与任何权利持有人有任何关联或授权。


站内搜索

证书荣誉

当前暂无信息

联系我们

  • 联系人: 吴工 女士
  • 话: 0592-5085207
  • 机: 18030175270
  • 资质公示 厦门阿米控技术有限公司 地址: 福建省 厦门市 思明区湖滨南路388号国贸大厦32D单元
  • 管理入口  技术支持:世铝网 长江有色
扫一扫,进入微商铺
您正在使用移动设备访问世铝网,您可以
浏览移动版,继续访问电脑版